• Products

    Dynamic Speakers

    BMR Speakers

    Dynamic Receivers

    Balanced Armature Receivers

    Buzzers

    Audio Exciters

    Boom Microphones & Sensors

    ECM Microphones

    MEMS Microphones

    Specialty Microphones

    IA Microphones

    Accelerometers

    Voice Vibration Sensors

    Acoustic Dampers

    Wax Protection

    Telecoils

    Programming Accessories

    Speaker Modules

    Microphone Modules

    RIC Modules

    ProxFusion Multi-Sensors

    ProxFusion Evaluation Kits

    ProxSense Capacitive Sensors

    ProxSense Modules

    ProxSense Evaluation Kits

    Neural Decision Processors

    DSP for Hearing Aids

    DSP for Hearing Aids Evaluation Kit

    Bluetooth Modules

    Bluetooth Modules Evaluation Kit

  • Acoustic Design Service

    Speaker Solutions

    Microphone Solutions

    Over the ear & In-ear Solutions

    Measurement Capabilities

    Electroacoustic Simulations

  • Engineering & Manufacturing

    Speaker Modules

    Microphone Modules

    Industrial Tools

  • Partners
  • About us
  • News
    • Acoustic Reviews
    • Events
    • Webinars
Contact Us
  • Products

    Dynamic Speakers

    BMR Speakers

    Dynamic Receivers

    Balanced Armature Receivers

    Buzzers

    Audio Exciters

    Boom Microphones & Sensors

    ECM Microphones

    MEMS Microphones

    Specialty Microphones

    IA Microphones

    Accelerometers

    Voice Vibration Sensors

    Acoustic Dampers

    Wax Protection

    Telecoils

    Programming Accessories

    Speaker Modules

    Microphone Modules

    RIC Modules

    ProxFusion Multi-Sensors

    ProxFusion Evaluation Kits

    ProxSense Capacitive Sensors

    ProxSense Modules

    ProxSense Evaluation Kits

    Neural Decision Processors

    DSP for Hearing Aids

    DSP for Hearing Aids Evaluation Kit

    Bluetooth Modules

    Bluetooth Modules Evaluation Kit

  • Acoustic Design Service

    Speaker Solutions

    Microphone Solutions

    Over the ear & In-ear Solutions

    Measurement Capabilities

    Electroacoustic Simulations

  • Engineering & Manufacturing

    Speaker Modules

    Microphone Modules

    Industrial Tools

  • Partners
  • About us
  • News
    • Acoustic Reviews
    • Events
    • Webinars
Contact Us
  • Products
  • Acoustic Design Service
  • Engineering & Manufacturing
  • Partners
  • About us
  • News
    • Acoustic Reviews
    • Events
    • Webinars
Menu
  • Products
  • Acoustic Design Service
  • Engineering & Manufacturing
  • Partners
  • About us
  • News
    • Acoustic Reviews
    • Events
    • Webinars
Contact Us

Search for specific product:

Categories:

  • Acoustic Components
  • Capacitive, Multifunctional Sensors
  • Processors
  • Wireless Systems

Latest News:

Watts Up? A simple formula for recalculating the SPL at different power and distance

12 June 2025

Have you ever stared at a loudspeaker datasheet, scratching your head while trying to figure out what the actual Sound Pressure Level (SPL)…

Read More »
« Previous Next »
Home / Acoustic Review / Stiffness controlled diaphragm as a possible sound attenuation solution

Stiffness controlled diaphragm as a possible sound attenuation solution

In the industrial and multimedia markets, managing loud noises is crucial to ensure good performance in audio systems. There are many techniques for attenuating sound hitting a microphone, but when the microphone is about to clip, the attenuation must be designed into the acoustic domain.

The goal of this article is to present a mechano-acoustic system that is well known in the industry: the stiffness-controlled diaphragm.

As shown in Figure 1, from the article by B. Fazenda and K. Griffiths [1], resonant diaphragms can be approximated by means of the damped mechanical mass-spring system.

Figure 1 – “diaphragmatic absorber” [1]

From the behavior of such a system, we know that the region around its resonance frequency can be divided into three zones:

– a region at the resonance controlled by the damping

– a mass-controlled region above resonance

– a stiffness-controlled region below the resonance.

Figure 2, from an article by D. Russell [2], illustrates these three zones for a system for which the normalized displacement x is calculated using the following formula:

F0 represents a normalized mechanical force (issued from the incoming acoustic wave in our case)

m represents the moving mass of the diaphragm

β represents the damping factor of the diaphragm

Ω represents the frequency

Ω0 represents the resonance frequency and is defined = √(k/m) with k the diaphragm stiffness.

Figure 2 - Displacement Response of a Driven, Damped Oscillator [2]

From this figure, we first understand that the displacement of the diaphragm below the resonance remains the same regardless of the frequency, but it also depends on the overall stiffness of the system. A decrease in stiffness for the system will result in both a decrease in resonance and an increase in diaphragm displacement. Conversely, an increase in stiffness will produce the opposite effect.

The relationship between displacement and acoustic attenuation can be predicted using the Lumped Element (LE) approach. Figure 3 below illustrates the LE network of the diaphragm which shows the mechano-acoustic couplings between incoming and outgoing pressures.

Figure 3 – Lumped Element electroacoustic network of a resonant diaphragm coupled to the acoustic pressure

By applying this network model to the response of a MEMS electrostatic microphone, we can predict its attenuated frequency response and compare it to the original response, like shown in Figure 4.

On this graph, the original microphone response is normalized to 1 kHz (orange curve) to evaluate the attenuation created by the diaphragm in the sound channel (blue curve). We observe that the system considered in example here provides a flat attenuation offset of 40 dB and slightly shifts the resonance frequency to the right. Such observed flat attenuation is a typical behavior of this system, in contrast to porous materials (e.g. dampers), which generally provide increasing attenuation with frequency.

Figure 4 – Lumped Element simulation of a stiffness-controlled diaphragm inserted in the sound channel of a MEMS Microphone

Let Seltech assist you in designing the correct attenuation solution for your device!

Discover more about our acoustic department

Review by:

Frédéric Fallais, Acoustic Application Engineer

Arthur Di Ruzza, Acoustic Technician

Sources:

[1]         B. Fazenda et K. Griffiths, «The Diaphragm Absorbers».

[2]         D. Russell, «Acoustics and Vibration Animations: Regions of Resonance,» 22 06 2019. [En ligne].

Available: https://www.acs.psu.edu/drussell/Demos/Resonance-Regions/Resonance.html. [Accès le 02 08 2021].

PrevPreviousSpeech Transmission Index: A proper way of evaluating the intelligibility of your system
NextSpeaker Enclosure Damping: A Few Directions for Proper AlignmentNext

Headquarters
SAS SELTECH
2, Allée des Cerisiers
F – 94042 Créteil FRANCE
Tel EU : +33 1 48 92 90 02
Tel NA : +1 (919) 481 6896

Products

  • Acoustic Components
  • Capacitive, Multifunctional Sensors
  • Processors
  • Wireless Systems
  • Acoustic Components
  • Capacitive, Multifunctional Sensors
  • Processors
  • Wireless Systems

Services

  • Acoustic Design Service
  • Engineering & Manufacturing
  • Acoustic Design Service
  • Engineering & Manufacturing

Legal

  • Terms & Conditions EU
  • Terms & Conditions US
  • Corporate Social Responsability
  • Legal Notices
  • Terms & Conditions EU
  • Terms & Conditions US
  • Corporate Social Responsability
  • Legal Notices

© Copyright 2025 SELTECH, All Right Reserved.